A split-system quote is easier to compare when everyone is pricing the same installation locations. The indoor unit affects the way a room feels and looks. The outdoor unit affects access, neighbours, usable outdoor space and the route between the two components. Choosing a spot simply because there is an empty wall can leave important questions unanswered.
This checklist helps Brisbane homeowners prepare a location brief before an installer visits. It does not replace a site assessment or the selected manufacturer’s installation requirements. Its purpose is to record how you use the property, identify constraints and make the final proposal easier to understand.

Start with the room you actually want to condition
Write down the room’s main use before marking a wall. A bedroom used overnight presents different preferences from a living room occupied in the afternoon or a home office used throughout the working day. Include when people arrive, whether doors generally remain open and which adjoining spaces you expect the system to serve.
Be specific about the boundary of the job. “Cool the lounge with the hallway door shut” is clearer than “cool downstairs”. If you expect air to reach around a corner or into another room, ask the installer to assess that expectation rather than assuming a larger unit will solve it. Room use is also helpful when comparing a single split system with another configuration.
The Australian Government’s YourHome heating and cooling guide explains the distinction between systems serving a room and central systems serving multiple spaces. It also describes the indoor and outdoor components of fixed split systems. Use that overview to frame the conversation, then ask for a recommendation based on your particular home.
Make a simple room sketch
You do not need architectural drawings to start. Draw the room outline and mark doors, windows, built-in cupboards, large furniture and the places people normally sit or sleep. Add approximate dimensions if you can measure safely from floor level. Label uncertain measurements rather than presenting estimates as exact.
Photograph the proposed wall from across the room as well as close up. A tight photograph of an empty wall can hide a tall cabinet, a nearby doorway or the route through the room. Take a wider image showing those relationships. Keep personal documents, family photographs and other private details out of images you send.
On the sketch, identify two possible indoor locations if practical. Write what you like and dislike about each: visibility from the entry, proximity to a work desk, the position of a bed or future furniture plans. These are preferences for the installer to consider, not instructions to install in an unsuitable location.
Discuss comfort at the occupied positions
Ask where the airflow would travel from each proposed location. Explain if someone dislikes a direct draught while sleeping or if a workstation is occupied for long periods. A location discussion should cover how the room will be used, not only whether the unit fits between two objects.
Also mention planned changes. A wall that is clear today may become a full-height wardrobe next year. Curtains may be replaced, a desk may move or a renovation may change the doorway. Recording those possibilities gives the installer a chance to explain whether they affect the proposal. Do not pay for a complex arrangement solely for a hypothetical renovation without considering how likely the change is.
Look outside before settling on the indoor wall
Walk around the property at ground level and identify potential outdoor locations. Note paths, gates, outdoor seating, garden beds and places used for storage. The purpose is to show the installer where equipment might conflict with everyday activities, not to determine technical clearances yourself.
Ask the installer to explain the required space around the selected outdoor unit, the proposed support arrangement and how a technician will reach it later. Ask what must remain clear after installation. Do not assume that a narrow side passage, balcony cupboard or decorative enclosure will be acceptable just because the equipment appears to fit.
Think about changes after installation too. A future fence, garden screen or stacked storage could affect the agreed arrangement. Keep the final location drawing with the equipment documents so that anyone landscaping or renovating the property can see what was planned.
Include neighbours and overnight use in the brief
Show the installer nearby bedroom windows and neighbouring living areas, particularly if the system will run overnight. Avoid treating a manufacturer’s published noise figure as proof that every installation location will comply. Ask how the proposed location and operating pattern have been considered.
Brisbane City Council’s noise guidance gives air-conditioning limits relative to background noise: 5 dBA from 7 am to 10 pm and 3 dBA from 10 pm to 7 am. The Council explains that relevant noise is assessed at a neighbouring property. Check the authority for your property’s council area rather than assuming every installation has the same assessment context.
The Australian Government’s YourHome noise-control guidance recommends considering sensitive rooms and neighbouring windows when positioning equipment. It also notes that acoustic screening needs to preserve airflow, access and manufacturer clearances. Do not build a box around an outdoor unit as a substitute for professional location advice.
Ask for the route and drainage approach to be shown
The finished appearance includes more than the two units. Ask where the connecting services and visible covers are proposed to run, where the wall will be penetrated and how condensate will be managed. Request an explanation of any visible pipework or covers before approving the quote.
If an alternative position requires a different route, ask for the difference to be described in writing. This helps you compare a straightforward proposal with one involving additional access or finishing work. It also makes clear which decorative repairs, painting or other building work are included and which would be separately arranged.
Do not open wall cavities, remove electrical covers, drill trial holes or disturb refrigerant pipework to investigate a proposed route. Queensland’s Electrical Safety Office advises using licensed professionals for electrical work. Ask which appropriately licensed contractor will undertake any required electrical work and how that scope is documented.
Separate permissions from the technical design
If you rent, live in a body corporate scheme or are changing a shared or externally visible part of a building, identify the relevant approval process before booking work. Give the decision-maker the proposed location and scope rather than a vague request for “an air conditioner”. Obtain advice about the permissions that apply to your property.
A useful approval pack includes an annotated photograph, the proposed equipment model, the outdoor position, visible routes and any access arrangements. Keep approval correspondence with the accepted quote. Approval of one location should not be assumed to cover a later move to another wall or balcony area.
Turn the discussion into a quote comparison
For each proposal, record the indoor location, outdoor location, service route, access arrangements, exclusions and unresolved questions. If one quote assumes a different location, ask why before comparing totals. A cheaper price based on a different scope is not a like-for-like comparison.
Ask what needs to be confirmed during the site visit and what might change the quote. Keep a dated version of the location sketch with the accepted proposal. If the installation team encounters an unexpected constraint, use that record to discuss the revised location and any cost or appearance implications before proceeding.
To discuss the options, review Coolmacks split-system air conditioning services and send your room sketch and location questions through the Coolmacks contact page. A clear brief will not replace technical assessment, but it gives the conversation a practical starting point.